Étude d'un filtre de neutrons épithermiques pour la thérapie par capture de neutrons : validation expérimentale de la simulation Monte Carlo

F. Colomb and G. Ermont

CEA-Saclay, DRE/SIREN, 91191 Gif-sur-Yvette cedex, France

Abstract
A part of Neutron Capture Therapy research bears on epithermal neutron beam design. This paper relates to the project of an epithermal neutron filter designed for the experimental reactor ISIS. This filter allows neutron energy spectrum adaptation to the tumor depth. The Monte Carlo code TRIPOLI 3 was used to simulate the filter response. The results from Monte Carlo simulations are compared to experimental results of neutrons spectra.

Résumé
Une partie de la recherche sur la Thérapie par Capture de Neutrons est consacrée à l'optimisation des faisceaux pour obtenir des neutrons d'énergie adaptée en fonction de la profondeur de la tumeur. Le but du projet décrit dans cette communication est la construction d'un filtre adaptable au réacteur de recherche ISIS. Une étude a été menée sur un dispositif préliminaire appelé "manchette" qui servira de support à divers écrans. Cette communication présente une comparaison des spectres obtenus par la simulation Monte Carlo et ceux obtenus expérimentalement à partir de détecteurs d'activation aux extrémités du dispositif.


Key words: Thérapie par Capture de Neutrons -- filtre épithermique -- code de Monte Carlo TRIPOLI 3
Contents