Vacuum UV actinometry. Ion current measurements with enclosed light sources
(Département de Chimie, Université Laval, Québec, P.Q., Canada, GIK 7 P4.), France.
Gas phase actinometry in the photoionization region was investigated via measurements of the current generated between collecting electrodes placed parallel or perpendicular to the light beam. The effects on the ion-current measurements of the space charge and of the distortion of the electric field by the LiF window and its metallic mounting were examined.
Résumé
On a examiné l’actinométrie par mesure du courant d’ionisation pour deux configurations d’électrodes collectrices : parallèles ou perpendiculaires à la direction des pilotons incidents. On a mis en évidence les effets sur la mesure du courant d'ionisation de la charge d’espace et de la distorsion du champ électrique au voisinage de la fenêtre transparente à l’ultraviolet à vide due à l’effet photoélectrique du LiF et il la présence de la monture métallique.